No generation, one forward pass: Radev beats GPT-5.4 on CT verdicts by ~19 points with ECE 0.01

Decision-Native Multimodal Clinical Modeling via Anatomical Grounding and Confidence Calibration

Juntao Jiang, Wenqi Zhong, Guangyu Guo, Dexia Chen, Yilong Hu, Yunhao Bai, Zhenyu Yi, Jianwei Xu, Tony C. W. Mok, Muxuan Gao, Ling Zhang, Yong Liu, Jiangning Zhang, Zhongwei Qiu

cs.CV

2026-11-25

Radev turns CT interpretation into single-pass candidate scoring with organ-grounded tokens and counterfactual calibration: 83.75% accuracy, 0.01 ECE on its new CT-Verdict benchmark.

What problem this solves

Most clinical questions put to a CT volume are closed-set: is the finding present, which organ holds it, how severe on a 0-to-4 scale. Current 3D medical VLMs answer them by generating free text autoregressively, then extracting a verdict. Three costs follow. Token-level probabilities from autoregressive decoding make poor confidence estimates, so a model can be right while its reported certainty is fiction. Local findings sit in a few slices whose relevance shifts with the question, and flat attention over long slice sequences is expensive and easily distracted by irrelevant anatomy. Answer-level supervision checks only correctness, never whether the model grounded its answer in the target organ, so background correlations can carry the score.

Clinically this is a hard constraint: missed findings delay intervention, false positives trigger unnecessary procedures, and a model with untrustworthy confidence cannot back an escalate-when-uncertain safety policy.

Method

Radev splits structured CT interpretation into three mechanisms.

Training runs in three stages on four 96GB H20 GPUs: projector-evidence alignment with the backbone frozen (1,000 steps, lr 1e-3), verdict fine-tuning (one epoch, 2e-5), then CCT (700 steps, 4e-6). The intent is explicit throughout: supervise the candidate distribution directly instead of reading probabilities off a generator, and intervene on the evidence instead of hoping calibration falls out of intact-input supervision.

Results

CT-Verdict-IID holds 56,825 questions over 5,080 abdominal CT studies (37,925 binary, 16,210 multiple-choice, 2,690 ordinal). Headline numbers:

ModelBinary AccChoice AccScore MAEBinary ECE
Radev-2B90.0871.330.390.01
Jev-1.14 (closed decision model)71.3950.990.600.04
HealthGPT-Pro-4B70.9637.501.050.10
GPT-5.470.2345.920.75n/a, no candidate probs

Radev-2B reaches 83.75% overall accuracy; the paper puts the gap to closed-source models at roughly 19 points. On the external multi-center cohort (421 AMOS-MM studies, 2,055 questions) it scores 72.72% binary accuracy against GPT-5.4's 63.93%, and 69.29% choice accuracy, 16 points over the strongest closed baseline. Ordinal KRPS lands at 0.028, about 3.8x below the best baseline (bootstrap 95% CI [2.44, 7.20]).

Calibration is the sharpest result. Fourteen of 22 baselines score worse than a constant-confidence reference that always reports overall accuracy; Radev posts a Brier skill score of 0.193 and top-label ECE of 0.010. Rejecting the least confident 20%, 40%, and 50% of cases lifts retained accuracy from 83.8% to 90.0%, 95.2%, and 97.0%; the best baseline (Jev-1.14) manages 77.6% at 50% deferral.

Ablations separate the contributions. Under identical data and fine-tuning, Radev-2B-VFT hits 89.91 binary accuracy versus 82.96 for Qwen3.5-4B and 80.36 for ClinFusion-8B, so the architecture drives the lead. CCT alone cuts binary ECE (x100) from 2.00 to 0.57 with accuracy holding.

Why it matters

The bottleneck for clinical deployment is rarely accuracy alone; it is knowing when the model is wrong. Radev's probabilities threshold directly into selective prediction and abstention, with a smooth accuracy-rejection curve that lets a workflow pick any point on the risk-workload frontier. Engineering-wise, the visual token count is fixed at 37 plus question-bound organs and inference is a single forward pass, so serving cost stays predictable. For medical multimodal teams, this is the first complete decision-native specimen on volumetric imaging, pairing architecture, objective, and benchmark. CCT itself is modality-agnostic and worth borrowing wherever confidence must track evidence.

The honest caveat: 83.75% is measured on a benchmark the authors built, so the absolute number follows its question distribution. The external cohort shows a larger lead, though, so this is not only benchmark familiarity.

Limitations