LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning
Md Rakibul Islam Prince, John Pelan, Zhiyuan Zhang, Adyaa Khera, Katherine Pesetski, Adeesh Desai, Akimizu Sugiyama, Minwoo Ki, Benjamin Alan Capelle, Temitope Ibrahim Amosa, Zijie Xu, Yihan Huang, Taehun Chung, Long Wang, Wei Li, Shaoting Lin, Yu She
cs.RO
2026-11-18
An open-source 3.5 mm optical taxel array senses three-axis force at every taxel via colored gel walls; added to an ACT policy, peg-in-hole success rose from 40% to 87%.
Touch covers what vision cannot: the moment a gripper closes, the object is hidden behind the fingers, and only contact tells the robot whether it holds anything, how hard, and where. Low-cost tactile arrays have spread through robot learning, and the workhorse is piezoresistive, a force-sensitive film read as a resistance matrix, thin, flexible, and cheap. But each taxel reports a single number, pressure only, no shear, and that number is a contact resistance through a polymer, so it drifts, saturates early, and depends on loading history. Camera-based sensors (GelSight, DIGIT) reconstruct the whole contact field at high resolution, but the camera's optical path forces them to be thick along the viewing axis, which makes them awkward to tile over a gripper. Magnetic skins (ReSkin, uSkin) do three axes per taxel and react to external magnetic fields. What was missing is an array that is both thin and per-taxel shear-capable.
LuxTac turns every taxel into an independent optical digital device.
The design logic: the reading is a geometric quantity, indentation depth, not a resistance. Viscoelastic drift stays out of the readout chain, and the real and simulated pads report the same quantity, which keeps sim-to-real alignment cheap.
The normal cartridge was characterized with a CNC indenter and a six-axis force/torque sensor; the shear cartridge was evaluated across three indenter shapes and nine held-out sessions.
| Metric | Result |
| Normal linearity | R2 = 0.999, 0.1–5.8 N, slope 0.170 FS/N |
| Repeatability / hysteresis | 2.0% / 5.9% FS |
| Three-axis force, held-out sessions | summed R2 0.96/0.96/0.92 (x/y/z), per taxel 0.92/0.93/0.94 |
| Shear-direction error | median 4.8° |
| Sim-to-real cosine | 0.942 (ceiling 0.9994, wrong baselines 0.594–0.763) |
| Peg-in-hole (15 trials) | 40% → 87%, Fisher p = 0.021 |
| Cube sorting (15 trials) | 33% → 40%, not significant (p = 1.0) |
Against comparable arrays: 3D-ViTac runs 32 Hz with no shear, FlexiTac and OpenTac run 100 Hz and infer shear from bump pressure patterns or magnets, while LuxTac streams 100–180 Hz with three axes per taxel. The ablation is clean: brightness-only features reach per-taxel R2 0.70/0.73/0.83, color-only 0.84/0.89/0.90, both together 0.92/0.93/0.94. The pad costs $100.74 and the readout board $37.52, with 97% of the pad cost in the converters, about $6.3 per taxel, scaling linearly.
For policy builders the value is form factor and information density, not raw precision: 3.5 mm mounts on a gripper finger, per-taxel shear is exactly the signal slip detection needs, and the simulator needs only four measured parameters per taxel, so fully sim-trained policies are a realistic path, though only static contact alignment is done so far. The gains are task-dependent: peg-in-hole went from 40% to 87%, while texture sorting stayed flat because the 4.4–4.8 mm pitch is coarser than the surface features, and the paper does not hide this. The scarce asset is the open-source stack, PCB design, fabrication procedure, firmware, characterization scripts, and simulator, a direct starting point for teams that want touch without building a sensor from scratch.
The authors' own list: the force estimate depends on contact shape, and a model trained only on contacts larger than one taxel drops to R2 ≤ 0.18 on a one-taxel circular indenter, so training data must include the smallest expected contact; the shear cartridge costs normal performance, with the full-scale reading drop falling from 21.9% to 15.9% of baseline and hysteresis rising from 5.9% to 9.1% FS; only three flat indenters were tested, with curved, sharp, and deformable objects untested; the characterization is quasi-static because the silicone creeps; LED output drifts with temperature and the baseline must be re-estimated before each episode; and the policies consumed pressure only, with shear not yet a policy input or simulated.
Two things stand out beyond that list. Per-taxel force labels come from distributing the measured total force by contact-area share, an assumption of uniform traction; the summed evaluation does not depend on it, but the per-taxel numbers do. And on the 16-taxel prototype most taxels sit on the border, so the few-shot adaptation results for a shared model were all measured on edge taxels, and interior behavior on larger arrays is extrapolation.